Turbine flow meter manufacturer with bjssae.com

Coriolis flow meters provider today: Should I measure mass flow rate or volumetric flow rate? It really depends on the goal of your application. When determining whether to use mass flow and volumetric flow, it is important to determine if you want to measure/control a set volume or the number of molecules of process fluid. When to use mass flow meter? As mass flow instruments are capable of precisely measuring and controlling how gas molecules flow into and out of a process, they are useful in many applications. It is possible to consider mass flow rates as molar flow rates since the number of molecules flowing through the measurement point remains constant regardless of temperature or pressure. Read additional info on https://www.bjssae.com/turbine-flow-meter.html.

Vortex flow meter is the fluid Reynolds number is within a certain range, and its output is only proportional to the volume flow. The output of vortex flowmeter has frequency signal and analog signal, and the analog output is obtained by f/ conversion on the basis of frequency output. This conversion loses about 0.1% accuracy. Therefore, when it is used to measure the steam flow, users prefer to use the frequency output. There are several other reasons why frequency output vortex flowmeters are more popular with users such as thermal companies.

Comprehensively consider the use requirements and procurement costs of gas turbine flowmeters. When the customized gas turbine flow meter did not appear in the domestic brand, the international brand can be said to be a super profitable product. A medium-sized gas turbine flow requires hundreds of thousands or even hundreds of thousands of yuan. And our domestic brands struggle tenaciously in a harsh environment where the strength and weakness are not an order of magnitude at all. It can be seen that when selecting a gas turbine flow meter, there are many factors to be considered, not only from before the purchase, but also after the purchase of the gas turbine flowmeter, all of which need to be considered. When choosing a gas turbine flowmeter, you must be careful!

Beijing Sincerity Automatic Equipment Co., Ltd is a research and development center, focusing only on one type of flow meter, the Coriolis mass flow meter, which has been in use for 33 years. Our Coriolis mass flow has reached the international leading level. We provide three types of Coriolis mass flowmeters, including U-shaped, micro-bent V-shaped and triangular, to meet the different needs of different industries. We can provide coriolis flow meter with ultra high pressure of 100MPa, ultra high temperature of 350 C, and minimum temperature of -300 C. We can also measure ultra-high viscosity liquids, such as 70,000 cps glue. We have been very successful with gas measurements such as hydrogen. In addition, we have been very successful in two-phase / three-phase / multiphase flow liquid measurement. We support OEM services. You can even customize the internal software for Coriolis mass flow meters. We also support market agents. Find even more info on https://www.bjssae.com/.

Sincerity, excellence in coriolis flow meter production with 33 years experience, Since 1987.Through continuous research, development and transformation, we have become the leader of the Coriolis Mass Flow Meters industries in China.Our products including coriolis mass flow meter,thermal mass flow meter,fork density meter and etc.We have 100+ workers and 5000+ factory,our customers from all over the world. We support OEM coriolis mass flow meter name plates.

It has been considered in the design that the steam becomes superheated, or it is difficult to determine which state it is in, or sometimes it is superheated and sometimes saturated, so the temperature and pressure compensation is adopted, and the above phase change has no effect on the measurement results. Considering saturated steam in the design, and adopting pressure compensation, the above-mentioned phase change will bring about a small error, that is, the compensation error caused by the density difference corresponding to the difference between the superheated steam temperature and the saturated steam temperature. The design is based on saturated steam, but temperature compensation is used, that is, the temperature of superheated steam is used as the saturation temperature to check the density table, which will generally cause large errors.

The Insertion Density Meters are equiped with the microprocessors inside, so the sensor could complete the signal conditioning, calculation and diagnosis functions, and it does not need the remote eletronic devices for processing. Typical industries applied include the petrochemical industiry, electricity power industry, wine industry, food industry, pharmaceutical industry, and mineral processing (such as, clay, carbonate, silicate, etc. ) For sepecific applications, the Insertion Density Meters are largely used in the interface detection of the multi-product production lines, density detection of the mixed liquid, end monitoring of the reaction kettle, and the separator interface detection.